Building Codes adopted effective date January 1,
2008
2007 Edition
California Building Code
2007 Edition California Electrical Code
2007 Edition California Energy Code
2007 Edition California Mechanical Code
2007 Edition California Plumbing Code
1997 Edition Uniform Housing Code
1997 Edition Uniform Code for the Abatement of
Dangerous Buildings
2006 Edition Uniform Solar Energy Code
2006 Edition Uniform Swimming Pool, Spa and Hot Tub
Code
|
Seismic Design |
See
CBC Section 1613 and ASCE 7-05 Chapter 11.
Use Google,
http://www.batchgeocode.com/lookup/
(or
other source) to determine site specific
longitude and latitude. Use USGS website
http://earthquake.usgs.gov/research/hazmaps/design/
or
NEHRP disk to determine S1 and Ss. |
|
Wind Design |
Basic Wind Speed
(fastest mile) 80 miles per hour
Basic Wind Speed (3-second gust) 95 miles per
hour
Importance factor, exposure and topographic
features are site and project specific. See ASCE
7-05, Chapter 6.
Use of Division of State Architect IR 16-7, Wind
Load Determination – Alternate Method, is
approved for use within the Town of Truckee. |
|
Soil and
Foundation |
Foundation and
soils investigation and reports are normally
required (CBC 1802.2).
If a soils report is not required, allowable
bearing pressure of 2,000 psf may be used unless
site conditions dictate less.
(Policy under review) |
|
Frost Depth |
For foundations
located below 7,000 feet elevation, the bottom
of exterior perimeter foundations shall be not
less than 18 inches below finished grade.
For foundations located above 7,000 feet
elevation, the bottom of exterior perimeter
foundations shall be not less than 24 inches
below finished grade.
Interior footings and foundations shall be
located a minimum of 12 inches below grade.
Exterior water lines shall be located a minimum
of 36 inches below grade. |
|
Snow Loads |
All of the Town
of Truckee is considered a snow area with ground
snow loads varying from 190 pounds per square
foot to 545 pounds per square foot depending on
the site location within the Town.
Please view the snow load chart showing
the snow loads in different subdivisions. If
that does not provide the snow load for the
project site in question, please fax or email
the Building and Safety Division for the site
specific ground snow load. Be sure to include
the project address or parcel number.
Email requests to
cdd@townoftruckee.com or fax requests to
(530) 582-7889 |
|
Climate Zone |
Climate Zone 16 |
|
Additional
Information |
Additional design
information can be found in the Town of
Truckee Municipal Code, Chapter 15.
Acrobat Reader is needed to view and print the
Municipal Code. To download a FREE copy, please
click on the icon below. |
|
|
| |
|
|
|
|
|
|
|
|
|
|
 |
|
|
 |
|
|
|
|
|
|
|
|
|
|
 |
 |
|
|